PRODUCTS



Home > PRODUCTS > Feeltek

Feeltek

[ Feeltek ]
3D Dynamic Focus System
FR70-C(C70)

사양
3-axis deflection units
support wavelength: 10640nm, 10200nm, 9400nm
XY2-100 protocol
processing of large working fields with small spot
high-end industry application, super performance
maximum 2000*2000mm work field
0.12@3508350mm@10640nm
0.64@2000x2000mm@10640nm
super large area marking
roll to roll leather marking
Data sheet
다운로드
브랜드
Feeltek

111

 

Super large work field Standard large field

Focal adjust option: automatic, manual.

                                                           222

 

 

Flexible large field processing

Through the dynamic focus system control, it can be 0.64@2000x2000mmwork field.

3337

 

Superfine spot size, super high speed.

FR70-C minimum spot line 0.12@350x350mm@10640mm.

 

 

 

   FR70-C superfine spot size, super high speed, smooth cutting effect, little heat impact.

 

 

 

 

   

   Leather cutting without sticking and charring.

 

 

 

 

 

 

Application Highlight

●  Roll to roll leather marking

●  Curved surface moving line marking

●  Filming

●  Drilling

888

                                                                   Super large field leather marking and cutting

                                               (widely used in sandpaper cutting, carbon fiber cutting, leather cutting )

 

 

Product Technical Information

 

Items Output Voltage(VDC) ±24
Current(A) 12A
Protocol XY2-100 Protocol
weight (KG) 34
Size(mm) 655*250*278

 

cooling condition Cooling Media Distilled or de-ionized water plus corrosion inhibitor
Termperature(°C) 22-28
Recommended cooling pressure(bar) 2-3
Recommended flow rate(l/min) 4-6

 

Optical Specifications Reflect mirror(mm) SIC
Wavelength(nm) 10600nm
Single lens transmission ≥99.7%
System transmission ≥82%
Aperture size(mm) ≤65mm
Subsystem inputbeam diameter(mm) 13.5~15mm
Coating index 1/2λ(PV)

 

Galvanometer
specifications
ScanAngle(°) ±11
Repeatability(μrad) 8
Max.Gain Drift(ppm/k) 100
Max.Offset Drift(μrad/k) 30
Long-term drift over 8h(mrad) ≤0.3
Tracking Error(ms) ≤1.2
Max.processing speed(dharaters/s) 8000mm/s@1200×1200;4000mm/s@650x650
Purge gas Purge gas N2(purity 99.95%)or Clean, Dry Air(purity 99.995%, oil free, 1 micron filtered)
* Other gas which not meet the specification stated above is not permitted to apply to this sub-system.

Large Field Version

Working Field
& Spot Diameter
Working Field(mm) 700x700 800x800 900x90o 1000x1000 1200×1200 1600×1600 2000×2000
The Min.Spot Diamneter@1/e2(mrm) 0.27 0.31 0.34 0.38 0.43 0.54 0.64
Focal length(mm) 761 881 1001 1121 1361 1841 2321

Small Field Version

working Field
&Spot Diameter
working Field(mm) 350x350 450x450 550×550 650×650 750x750 850x850
The Min.Spot Diameter@1/e2(mm) 0.134 0.162 0.188 0.221 0.251 0.282
Focal length(mm) 341 461 581 701 821 941

 

 